Home > Our Products > DETECTORS > VexTrace

VexTrace

VexTrace can detect and identify a wide variety of explosives including pure explosives and composite explosives under different humidity and pressure conditions in vapour and trace (particles) modes.

The list of explosives includes: TNT, RDX, C4, Semtex, PETN, ANFO, EGDN, Nitroglycerine (NG), Dynamite, DNT, Black Powder, Ammonia and Urea nitrates, HMTD, Tetryl, HMX, PICRIC ACID and mixtures thereof.

The cost of ownership of VexTrace is very low, as no special consumables are required. Regular aluminium foil wipes are used for sampling in the trace mode.

VexTrace runs on the Field Asymmetric Ion Mobility Spectrometry principle. VexTrace contains no radiation sources. Corona discharge functions as the source of ionization.

VexTrace features user authorization function with the internal memory which allows to save more than 5OO K results of analysis.

  • no special calibration required
  • warms up in only 30 sec
  • easy to use, no special training required

Presence of an explosive is visualized on the LCD display of the device or any Wi-Fi device usable as a remote control.

GPS option allows to determine the coordinates of the device when an alarm is detected and save the information to the database.

Optional built-in searching radiometer in intended for measuring g-ray dosage. It allows fast and effective detection of radiation sources with extra short exposure time.

VexTrace delivers rapid and reliable detection of a wide spectrum of military, commercial, and homemade explosives — even in challenging environments. It operates effectively in both vapor* and trace (particle) detection modes.

VexTrace combines portability, rapid startup, and exceptional ease of use. Operators can begin detection within seconds — no prior training required.

With no expensive consumables or frequent maintenance requirements, VexTrace offers one of the lowest ownership costs in its class.

KEY FEATURES:

  • easy to use, no special training required
  • warms up in only 20 sec
  • Remote management and data archiving via Ethernet/Wi-Fi.
  • Self-cleaning and self-diagnostic functions; no manual calibration.
  • No special consumables required
  • Internal backup battery for continuous operation.
  • Expandable explosive database.
  • Direct integration with monitoring systems via standard TCP/IP and XML protocols. 
  • Remote control via a web application; no special software needed.
  • On-board storage of analysis results.
  • Weight is less than 2 kg

Detection Principle:

  • Analytical detection principle: Field Asymmetric Ion Mobility Spectrometry
  • Sample ionization method: Corona discharge. No radioactive source is used. 

Optional built-in searching radiometer (VexTrace-RM version):

  • Measuring gamma-ray dosage
  • Exposure dose measure range: 0...0,5 mSv/hr.
  • Photon energy counting range: 30...3000 keV
  • Operation exposure time: 1 sec

VexTrace - General Specifications

Sensitivity threshold in vapor mode (for TNT at 20 °C

and 80 % humidity)

10-14 g/cm3, 1 ppt (Better than 10-13 g/cm3)

Threshold sensitivity in particle mode (for TNT)

100 pg

Technology

Field Asymmetric Ion Mobility Spectrometry (FAIMS)

Radiation source

No

Calibration

Not required

Type of ionization

Corona discharge

Alarm type

Audio and visual, with substance identification

Warm up time

30 sec

Analysis and results time

1-6 sec

False alarm rate

Less than 1 %

Time of work from standard/extended battery

2 / 4 hours

Display

109 mm (4.3 inches) color TFT display with touch screen

Operating temperature

From -15 °C to +55 °C

Operation humidity at 25 °C

95% non-condensing

Operation altitude

Up to 5 000 m

Dimensions (LxWxH), weight

405x127x160 mm, 2 kg

GPS option

Available

 

Optional built-in searching radiometer:

Exposure dose measure range: 0.1 uSv/h.. 0.01 Sv/h

Photon energy counting range: 30...3000 keV

Operation exposure time: 1 sec

VexTrace is efficient both indoors and outdoors at temperatures above zero